1. Project Profile
1.1 Project Background
Lujiatan Wetland Sports Park covers 33 mu, equipped with two 8-a-side and two 5-a-side football pitches, hosting city & provincial football tournaments. Outdated old lights caused insufficient brightness, severe glare and high power consumption, failing Class III professional match standards. CPS Lighting, a reliable sports lighting supplier, delivered full turnkey outdoor football lighting renovation covering design, lamp supply and construction.
1.2 Project Demand
Standard baseline: Meet JGJ Class III professional football match standard
Optical indicators: Average illuminance ≥500lux, uniformity U2≥0.6, strict glare & light spill control
Layout solution: Adopt bilateral pole layout for all four football fields
Product matching: Mix 250W & 150W outdoor professional stadium lights for layered lighting
Outdoor reliability: IP66 waterproof & dustproof, long service life utilizing professional LED stadium lights, low operation cost
2. Performance Evaluation

3. Design Standard: JGJ & FIFA Sports Lighting Classification
Design complies with JGJ153-2016 Sports Stadium Lighting Design & Inspection Standard:
This training base undertakes official city-level football events, fully designed to reach Class III professional match grade.
4. Customized Full-package Solution by CPS Lighting
4.1 Lamp Configuration

4.2 Core Technical Advantages
Targeted bilateral pole layout: Scientific beam angle design eliminates dead zones on pitch edges
Anti-glare precision optical lens: Restrain stray light, protect athletes’ vision during night games
All-weather outdoor performance: IP66 integrated enclosure, adapt rain, fog and temperature fluctuation
Mixed power collocation: Match large & small pitches separately to balance lighting effect and energy saving
Classic HD broadcast lamp series for large stadium upgrading:
SPL02 Series: 500W/1500W options, cold-forged pure aluminum integrated fin heat sink, high brightness & low glare
SPL01 Series: 500W/1000W options, independent precision lens, high luminous efficiency
4.3 Acceptance Outcome
Third-party testing proves all pitches hit over 500lux average illuminance with uniformity above 0.6. Soft, evenly distributed light effectively reduces glare and light pollution, perfectly satisfying provincial & municipal football events. The energy-saving LED system gains consistent recognition from the Football Association and football lovers.

5. Case Photos




6. Cooperation Information
1) Business Scope
Global design & supply of professional sports lighting systems;
Customized lighting solutions and ODM/OEM customization services for new builds & renovations of indoor/outdoor stadiums, applicable for extreme environments including Category 16 typhoons, -40℃ frigid cold and 60℃ high temperatures.
2) Service Commitment
Professional optical simulation reports via DIALux / AGi32 lighting simulation;
Long-term quality warranty ranging from 3 to 10 years, ensuring stable operation under global standards.