[Football] Grade III Stadium Lighting Solution & Tech Guide

1. Project Overview & Standards

This design proposal provides a high-efficiency LED sports lighting solution tailored for standard outdoor football pitches. The scheme aims to deliver clear visual conditions for athletes, referees, and spectators, while adhering strictly to international and national standards for glare reduction, energy saving, and light spill prevention.

  • China Standard: JGJ 153 standard (JGJ 153-2016 Sports Stadium Lighting Design)

  • Governing Regulations: CFA (Chinese Football Association) technical guidelines & FIFA Stadium Lighting standards


2. Technical Parameters & Requirements

  • Target Illuminance: Match Mode (≥500 lux), Training Mode (~350 lux), Daily Mode (~150 lux)

  • Uniformity: Maintained illuminance uniformity U1/U2 ratios optimized via simulation

  • Quality Control: Color Rendering Index Ra ≥ 80, CCT 5000K-5700K, Glare Rating GR < 50


3. Luminaire & Installation


Asymmetric Layout (4-corner Poles, 5~8m from sidelines)

  • Corner-facing lamps: Narrow asymmetric beams for far pitch coverage

  • Midfield-facing lamps: Medium asymmetric beams for central areas

  • Calibrate angles via DIALux lighting simulation; Max/Min illuminance ratio ≤ 1.5


4. Intelligent Control System


Architecture

4G/5G remote module + local control cabinet supporting DMX512 / DALI control + APP / Web management


Preset Modes

  • Match Mode: 100% power, ≥500 lux

  • Training Mode: 70% power, ~350 lux

  • Daily Mode: 30% power, ~150 lux

  • Energy-saving Mode: 10% power for basic safety lighting


Features

Features an intelligent dimming system supporting timed auto-switch & venue system linkage; achieving ≥25% energy savings vs traditional metal halide lamps.


5. Construction & Commissioning

  • Structural check: Verify pole load (≈1.5 tons/pole) and wind resistance via structural safety certification specifications

  • Pre-assemble lamps on brackets for integral hoisting and quick wiring

  • On-site commissioning steps: Laser angle marking → spot tuning → grid illuminance uniformity U1/U2 test → DIALux lighting simulation fine-tuning → glare and anti-light spill control inspection

  • Acceptance standard: China's JGJ 153 standard (JGJ 153-2016) & CFA regulations


6. CPS LED Sports Lighting Selection List