[Hockey Ball] Grade III Indoor Lighting Retrofit Project

1. Project Profile

1.1 Project Background

Basic Venue Information Table

Defects of Original Lighting System

The indoor hockey venue was equipped with 50 units of 400W metal halide lamps, with obvious drawbacks affecting daily training:

  • High power consumption, slow startup response, severe light decay, short service life

  • Partial lamps damaged, insufficient average illuminance & uneven light distribution, failing training lighting standards

  • Excessive blue light, serious glare, low color rendering, poor visual comfort

  • Difficult for athletes to track hockey balls, easily causing visual fatigue and eye damage

  • The base launched full lighting upgrading and adopted CPS customized LED Court Light & Indoor Sports Lighting solution to build a healthy, high-quality sports light environment.


1.2 Core Project Requirements

  • Energy-saving replacement: One-to-one lamp replacement, total power reduced by 50%, cut long-term electricity and maintenance cost, meet Energy-saving LED Sports Light standard

  • Illumination index: Average horizontal illuminance ≥500lx, uniformity ≥0.8, reach Class II standard for amateur matches & professional training

  • Optical performance: Built-in anti-glare structure, adopt Flicker-free Broadcast Grade Lighting, high color rendering for clear ball tracking

  • Climate adaptability: Stable long-term operation under large temperature difference of sub-plateau region

  • Full engineering service: Complete set of lighting design, product supply, on-site guidance, post-installation testing & after-sales service

2. Performance Evaluation

Before & After Lighting Parameter Comparison Table


Post-renovation Core Advantages

  • Significantly reduce power and maintenance expense, classic high-efficiency Energy-saving LED Sports Light

  • Equipped with High Uniformity Illuminance Stadium Light, realizing full-court soft and balanced lighting

  • Multi-layer deep cavity optical lens suppress stray light, professional Anti-glare LED Stadium Light effectively protect athletes’ eyesight

  • Split modular design, only replace faulty single module instead of whole lamp, lower later maintenance workload

  • Wide temperature working range, stable operation all year round for sub-plateau comprehensive training venues

3. Design Standard: JGJ & FIFA Sports Lighting Classification

3.1 Domestic Design Standard

  • As a National & Industrial Lighting Standard Drafter, CPS Lighting strictly designs the whole project in accordance with JGJ 153-2016 national sports lighting code. Centering on the venue’s professional training and competition positioning, the solution takes Class III professional competition lighting standard as the core design benchmark, and reserves multi-scene mode switching to meet amateur training and daily fitness needs.


3.2 FIFA International Reference Standard

  • FIFA Level E standard is applicable to daily training venues, illuminance range 500–1000lx, consistent with this project’s core indicators

  • The whole lighting scheme follows core specifications of FIFA Standard Stadium Lighting: anti-glare, flicker-free, uniform light distribution

  • All layout and optical design complies with professional Sports Lighting Design Guide

4. Customized Full-package Solution by CPS Lighting

CPS is a professional Sports Lighting Manufacturer, drafter of national & industrial lighting standards, dual Class A lighting engineering enterprise, ISO-certified factory with national patent awards, with 1000+ Completed Global Sports Lighting Projects delivered worldwide.

4.1 Core Product: 200W Special Indoor Hockey LED Court Light

Product Parameter Specification Table

Product Highlights

  • Direct one-to-one replacement for traditional 400W metal halide lamp with remarkable energy-saving effect

  • Independent modular structure, effectively cut later maintenance cost

  • Deep cavity stray light suppression design, professional certified Anti-glare LED Stadium Light

  • Wide temperature tolerance, perfectly match sub-plateau comprehensive training venues

  • Balanced uniform light output fully meet Class II training venue lighting requirements

4.2 Full Lifecycle One-stop Service System

  • Pre-project: Free lighting simulation calculation & venue layout drawing design

  • Mid-project: Self-owned factory production, support Sports Lighting OEM & ODM Factory customization + on-site technical installation guidance

  • Post-project: Complete Full Lifecycle Sports Lighting Service, regular illuminance inspection and rapid after-sales response

Enterprise Core Qualification Keywords

  • Specialized & Sophisticated SME Sports Lighting

  • Sports Lighting Factory with ISO Certification

  • National Excellent Patent Award Sports Lighting

5. Case Photos


6. Cooperation Information

1)Business Scope

  • Global design & supply of professional sports lighting systems;

  • Customized lighting solutions and ODM/OEM customization services for new builds & renovations of indoor/outdoor stadiums, applicable for extreme environments including Category 16 typhoons, -40℃ frigid cold and 60℃ high temperatures.


2)Service Commitment

  • Professional optical simulation reports via DIALux / AGi32 lighting simulation;

  • Long-term quality warranty ranging from 3 to 10 years, ensuring stable operation under global standards.