1. Project Profile
1.1 Project Background
To boost students’ physical fitness, Shenyang City University launched a full sports lighting renovation covering roller rink, basketball courts, tennis courts and football field. Old dim metal halide lamps caused uneven brightness, high energy consumption and frequent failures. CPS Lighting supplied full LED lighting scheme with intelligent control system, completing design and construction within 60 days.
1.2 Project Demand
Classification Standard: Roller/basketball/tennis courts reach Class II training grade; football field meets Class III professional match standard
Optical Parameters: Roller rink ≥510lux, basketball ≥600lux, tennis ≥500lux, football ≥550lux
Layout Design: 10m 4-side poles for ball courts; 15m four-corner high poles for football pitch
Product Requirement: Adopt SPLH Series & TSC Series with high reflectivity and efficient heat dissipation
Intelligent Function: Multi-scene dimming system for cleaning, training and competitions
2. Performance Evaluation

3. Design Standard: JGJ & FIFA Sports Lighting Classification
Design strictly follows JGJ153-2016 Sports Stadium Lighting Design & Inspection Standard:
Ball training grounds adopt Class II standard, while the football field is upgraded to full Class III match level.
4. Customized Full-package Solution by CPS Lighting
4.1 Lamp & Layout Configuration

4.2 Core Technical Advantages
SPLH Series Exclusive Performance: Multiple optional beam angles, reflectivity up to 92%, pure copper riveted fin heat sink, fast cooling, anti-fog & anti-condensation design.
TSC Series Football Special Lights: Matched 15m high pole four-corner layout, uniform full-field illumination without blind spots.
Intelligent Dimming Control System: Support one-key switching of cleaning, amateur training, amateur match and professional match modes via panel & tablet.
Full-cycle Service: Finished scheme design + construction within 60 days, minimal impact on campus daily sports.
4.3 Acceptance Outcome
All venues passed on-site inspection. Multi-sport areas reach stable Class II training illuminance; football pitch hits 550lux average brightness to satisfy school-level competitions. Intelligent control greatly reduces daily power consumption, highly recognized by school logistics and sports department.
5. Case Photos


6. Cooperation Information
1) Business Scope
Global design & supply of professional sports lighting systems;
Customized lighting solutions and ODM/OEM customization services for new builds & renovations of indoor/outdoor stadiums, applicable for extreme environments including Category 16 typhoons, -40℃ frigid cold and 60℃ high temperatures.
2) Service Commitment
Professional optical simulation reports via DIALux / AGi32 lighting simulation;
Long-term quality warranty ranging from 3 to 10 years, ensuring stable operation under global standards.