[Football] Grade IV Comprehensive Lighting Retrofit Project

1. Project Profile

1.1 Project Background

1.1.1 Project Overview

Scheduled for completion in 2026, the Macheng Sports Center lighting project is a comprehensive municipal sports venue upgrading project. Covering multiple sports functional venues, the project adopts high-performance TLX series professional sports lamps from CPS Lighting. After full completion, all lighting technical indicators fully meet JGJ153-2016 Grade IV TV broadcast competition standards, delivering professional, high-standard light environment for official sports events, daily training and public fitness activities.

1.1.2 Venue Scale

The project adopts the mainstream one stadium and two halls overall layout, covering three core sports venues:

  • Outdoor Athletics & Football Field (Main Stadium): Covering an area of 16,000 ㎡ with 15,200 spectator seats, it supports professional track and field, football competitions and large-scale outdoor cultural and sports events

  • Indoor Comprehensive Sports Hall: Covering an area of 15,000 ㎡ with 5,000 spectator seats, applicable to indoor competitive events including basketball, volleyball and badminton

  • Indoor Natatorium: Professional swimming sports and daily fitness venue, enriching the multi-functional sports service system of the sports center

Scale Diagram 1      Scale Diagram 2

1.1.3 Project Demand

As a multi-functional comprehensive sports center, the venue requires unified professional graded lighting construction. The lighting system needs to adapt to different sports scenarios, achieve high uniformity, low glare and stable illumination, fully meet Grade IV TV broadcast-level competition requirements, and support high-definition event shooting, live broadcast, professional training and public fitness services.


2. Pre & Post Renovation Performance Evaluation

2.1 Pre-renovation Lighting Defects

  • Unified Standard Missing: Traditional scattered lighting could not form unified professional venue lighting standards

  • Insufficient Event Adaptability: Failed to reach Grade IV TV broadcast competition standard, unable to host formal high-level sports events

  • Poor Optical Performance: Uneven illumination and obvious glare affect athletes’ competitive state and visual judgment

  • Single Application Scenario: Only suitable for daily casual sports, lacking professional competition-level lighting performance

Defects Overview

2.2 Post-installation Performance Upgrade

  • Professional Standard Upgrade: All venue lighting indicators fully comply with JGJ153-2016 Grade IV TV broadcast competition standard

  • Multi-scene Matching Upgrade: Adapt to outdoor track and field, football, indoor basketball, swimming and other multi-sport scenarios

  • Optical Quality Upgrade: Realize full-venue uniform illumination, ultra-low glare, stable and professional competitive light environment

  • Event Guarantee Upgrade: Support formal sports competitions, HD live broadcast and slow-motion replay of regional high-level events

3. Design Standard: JGJ & FIFA Sports Lighting Classification

3.1 Domestic Design Standard

  • Compliance Specifications: GB50034-2013, JGJ153-2016 Standard for Lighting Design and Testing of Sports Venues

  • Execution Lighting Grade: Grade IV Professional Competition & TV Broadcast Level

  • Applicable Scenarios: Regional official sports competitions, professional sports training, public fitness and sports popularization

3.2 International Reference Standard (FIFA)

The overall lighting layout and optical design refer to international professional sports venue lighting specifications. Strictly optimize core indicators such as illuminance uniformity and glare value to meet the basic lighting guarantee requirements of multi-type formal sports events.

4. Customized Full-package Solution by CPS Lighting

4.1 Solution Overview

Aiming at the multi-functional and multi-scene operation characteristics of Macheng Sports Center’s “one stadium and two halls”, CPS Lighting customized an integrated professional sports lighting solution. Adopting exclusive TLX series professional sports lamps, the solution realizes standardized and unified lighting upgrading for all venues, meeting Grade IV TV broadcast competition standards and multi-sport professional lighting demands.


4.2 Core Venue & Product Matching

Core Venue & Product Matching Table


Fixture Spec 1      Fixture Spec 2

5. Case Comparison Photos


5.1 Pre-installation Lighting Status

  • Unified professional lighting standard missing for each functional venue

  • Ordinary lighting with uneven brightness and obvious visual glare

  • Unable to support Grade IV TV broadcast-level formal sports events

  • Low overall venue lighting grade, restricting high-level event holding

5.2 Post-installation Lighting Effect

  • All venues achieve full-area uniform and high-brightness professional lighting

  • Ultra-low glare and high color rendering, creating a professional competitive sports atmosphere

  • Fully meet Grade IV TV broadcast competition standards for various sports events

  • Satisfy multi-dimensional demands of official competitions, professional training and public fitness

Effect 1      Effect 2      Effect 3

Effect 4      Effect 5



Keywords:

Macheng Sports Center, comprehensive sports venue lighting, outdoor football field lighting, indoor basketball gym lighting, JGJ153-2016 Grade IV, TV broadcast sports lighting, TLX series sports lamp, multi-functional stadium lighting, low glare sports lighting, professional competition venue lighting, public sports center lighting